2

Connection Conflicts with USB Debuggers


Avatar
Tim

We've received reports of our logic analyzer connection becoming unstable when a USB debugger (such as ST-Link V2) is connected to the same PC.

A common workaround is described below:
1. disconnecting ST-Link (remove USB cable)
2. Start Logic 2
3. connect Logic Pro 8, a connection is possible now
4. connect the ST-Link again
So hopefully this helps in the trouble shooting

Let us know here if you are running into the same issue!

A

Activity Newest / Oldest

Avatar

Tim

(#84680)
"sometimes it interferes my debugger tool (could not connect my tool), that I close the Saleae software and open it, after my debugger tool has connected. This solve the issue. So I am searching for a button to disconnect and connect Saleae."


Avatar

Tim

(#60085) [a recent report of this issue]
"If a my debugger ST-Link V2 is connected to my PC, the LogicAnalazer can't beconnected :-)! Funny but true...
For me, i found a working a reliable workaround:
1. disconnecting ST-Link (remove USB cable)
2. Start Logic 2
3. connect Logic Pro 8, a connection is possible now
4. connect the ST-Link again
So hopefully this helps in the trouble shooting"