In I2C analysis csv export the records end time stamps are on wrong position

In I2C analysis csv export the start timestamp is at first clock rise which is OK, but the end time point is at the start of the next package that can be very far away in time, and not related to the current pointed data. 
The correct time setting should be at first clock rise (as is now), the end time should be at the last clock fall (the 9th,ack pulse)>
This will also be at the beginning and the end of the blue lines. Just copy the blue lines times that you already have.  

  • samuel tal
  • Sep 16 2018
  • Needs review